Post Frame Building - Retrofit Wall White
Product: Reflective One Side
Inside the Girts: Open Interior
R-4.2* Heat Flow Horizontal
* Includes thermal resistance of 0.68 interior air film.
Calculation Disclaimer: All values are calculated based on the "ASHRAE Handbook of Fundamentals".
Tempshield™ Insulation products are a group of technologically advanced materials. They are ideal for new construction or retrofit applications in commercial, industrial, metal and post/frame buildings, along with many other DIY applications. When you think of insulation, you should think of Tempshield™. Our products are recognized for their thermal performance, easy installation, versatility, price and environmental friendliness.
Standard Size Recommended Products:
- 48" x 100' White Double Bubble Reflective
- 48" x 125' White Double Bubble Reflective
- 72" x 125' White Double Bubble Reflective
Custom Size Recommended Products:
- 60" x 50' White Double Bubble Reflective
- 60" x 100' White Double Bubble Reflective
- 72" x 50' White Double Bubble Reflective
- 72" x 100' White Double Bubble Reflective
- 84" x 50' White Double Bubble Reflective
- 84" x 100' White Double Bubble Reflective
- 96" x 50' White Double Bubble Reflective
- 96" x 100' White Double Bubble Reflective
- 108" x 50' White Double Bubble Reflective
- 108" x 100' White Double Bubble Reflective
- 120" x 50' White Double Bubble Reflective
- 120" x 100' White Double Bubble Reflective
Benefits:
- Easy to handle and install
- Convenient roll sizes
- Class A / Class 1 Fire Rating
- Inhibits dew point condensation
- Vapor retarder (0.02 perms)
- Does not compress, collapse or disintegrate
- Non-toxic / non-carcinogenic
Testing and Certification:
Tempshield™ products are thoroughly tested at either nationally approved independent laboratories or leading universities. Tests are performed to current American Society of Testing and Materials (ASTM) standards when a standard exists. For a copy of an actual test report, please e-mail us at customer.support@insulationstop.com.
Air Space Requirements:
Post Frame Building Air Space Requirements
Installation Instructions:
Post Frame - Retro Wall White - Installation Instruction
- The Tempshield™ Insulation is installed with the “white side” towards the interior of the building.
- Pre-installation inspection - Check the roof area for clutter, water sprinklers, conduit and lights. Sprinkler systems are especially important. All water pipes must be below the Tempshield™ Reflective/Bubble/Bubble/White Insulation to prevent the possibility of freezing in the winter.
- empshield™ Reflective/Bubble/Bubble/White Insulation can be installed either vertically or horizontally.
- Attach the product to the inside of the girts using 5/16” staples.
- Staple product at approximately 4” intervals into the girts.
- Tape the seams with a Tempshield™ Foil Tape (goal is an air-tight, snug seam seal).
Important: Review These Important Safety Guidelines Prior to Installation.