Post Frame Building - New White Roof- Above or Below Purlins
Post Frame Building - Product: Reflective One Side
Below the Purlins: Open Interior
R-6.4* Heat Flow Down / R-3.7* Heat Flow Up
Above the Purlins: Open Interior
R-3.8* Heat Flow Down / R-3.5* Heat Flow Up
* Includes thermal resistance of 0.61 UP and 0.92 DOWN for interior air film.
Calculation Disclaimer: All values are calculated based on the "ASHRAE Handbook of Fundamentals". Heat flow up and down
Tempshield™ Insulation products are a group of technologically advanced materials. They are ideal for new construction or retrofit applications in commercial, industrial, metal and post/frame buildings, along with many other DIY applications. When you think of insulation, you should think of Tempshield™. Our products are recognized for their thermal performance, easy installation, versatility, price and environmental friendliness.
Standard Size Recommended Products:

- 48" x 100' White Double Bubble Reflective
- 48" x 125' White Double Bubble Reflective
- 72" x 125' White Double Bubble Reflective
Custom Size Recommended Products:
- 60" x 50' White Double Bubble Reflective
- 60" x 100' White Double Bubble Reflective
- 72" x 50' White Double Bubble Reflective
- 72" x 100' White Double Bubble Reflective
- 84" x 50' White Double Bubble Reflective
- 84" x 100' White Double Bubble Reflective
- 96" x 50' White Double Bubble Reflective
- 96" x 100' White Double Bubble Reflective
- 108" x 50' White Double Bubble Reflective
- 108" x 100' White Double Bubble Reflective
- 120" x 50' White Double Bubble Reflective
- 120" x 100' White Double Bubble Reflective
Benefits:
- Easy to handle and install
- Convenient roll sizes
- Class A / Class 1 Fire Rating
- Inhibits dew point condensation
- Vapor retarder (0.02 perms)
- Does not compress, collapse or disintegrate
- Non-toxic / non-carcinogenic
Testing and Certification:
Tempshield™ products are thoroughly tested at either nationally approved independent laboratories or leading universities. Tests are performed to current American Society of Testing and Materials (ASTM) standards when a standard exists. For a copy of an actual test report, please e-mail us at customer.support@insulationstop.com.
Air Space Requirements:
Post Frame Building Air Space Requirements
Installation Instructions:
Post Frame - New White Roof Above and Below Purlin- Installation Instruction
1. Metal Roof with Product below Purlin (first illustration)
- The Tempshield™ Insulation is installed with the “white side” towards the interior of the building.
- After the trusses are set, run two purlins to make sure the trusses stay true.
- Attach the Tempshield™ Reflective/Bubble/Bubble/White product to the first truss with at least 5/16” staples. Temporarily nail a 2”x 4” block over the end of the product to prevent it from pulling away.
- Roll out the product across the top of the trusses, pull tight and staple.
- Run subsequent courses of the product with a 3/4” overlap at the seams.
- Tape the seams with a Tempshield™ Foil Tape (goal is an air-tight, snug seam seal).
- Install purlins over the insulation. Nail or screw to the trusses through the product.
- Install the metal roof to the purlins.
2. Metal Roof with Product above Purlin (second illustration)
- Per instructions above except install Tempshield™ after installing the purlins.
- When installing product, insure that a minimum of a 3/4” drape (middle of cavity) is present.