Metal and Steel Building - White Retrofit Wall

Metal and Steel Building White Retrofit WallProduct: Reflective One Side



Open Interior
R-3.5* Heat Flow Horizontal

* Includes thermal resistance of 0.68 interior air film

Calculation Disclaimer: All values are calculated based on the "ASHRAE Handbook of Fundamentals".

Tempshield™ Insulation products are a group of technologically advanced materials. They are ideal for new construction or retrofit applications in commercial, industrial, metal and post/frame buildings, along with many other DIY applications. When you think of insulation, you should think of Tempshield™. Our products are recognized for their thermal performance, easy installation, versatility, price and environmental friendliness.

Standard Size Recommended Products:

Custom Size Recommended Products:

Testing and Certification:

Tempshield™ products are thoroughly tested at either nationally approved independent laboratories or leading universities. Tests are performed to current American Society of Testing and Materials (ASTM) standards when a standard exists. For a copy of an actual test report, please e-mail us at customer.support@insulationstop.com.

Air Space Requirements:
Metal and Steel Building Air Space Requirements

Installation Instructions:
Metal and Steel Building - Retrofit Wall White - Installation Instruction

  • The Tempshield™ Insulation is installed with the “white side” towards the interior of the building.
  • Pre-installation inspection - Check the roof area for clutter, water sprinklers, conduit and lights. Sprinkler systems are especially important. All water pipes must be below the Tempshield™ Reflective/Bubble/Bubble/White Insulation to prevent the possibility of freezing in the winter.
  • Install 1”x 2” furring strips on the inside and perpendicular to the Z girts on 22” centers. Utilize 1 1/4” self-taping sheet metal screws to secure the furring strips to the Z girts.
  • Butt the furring strips together and tape. Staple tape for reinforcement.
  • Staple the edges of the Tempshield™ Reflective/Bubble/Bubble/White product to the furring strips with a 3/4” overlap at the seams.
  • Tape the seams with a Tempshield™ Foil Tape (goal is an air-tight, snug seam seal).
  • Staple product at approximately 4” intervals down the middle of the sheet into the furring strip parallel and centered.

Important: Review These Important Safety Guidelines Prior to Installation.