Metal and Steel Building White New WallProduct: Reflective One Side



Open Interior with a 3/4" Thermal Break
R-4.6* Heat Flow Horizontal

Open Interior with a Nominal 3/4" Drape in Product (No Thermal Break)

R-3.7* Heat Flow Horizontal

* Includes thermal resistance of 0.68 interior air film

Calculation Disclaimer: All values are calculated based on the "ASHRAE Handbook of Fundamentals".

Tempshield™ Insulation products are a group of technologically advanced materials. They are ideal for new construction or retrofit applications in commercial, industrial, metal and post/frame buildings, along with many other DIY applications. When you think of insulation, you should think of Tempshield™. Our products are recognized for their thermal performance, easy installation, versatility, price and environmental friendliness.

Standard Size Recommended Products:

Custom Size Recommended Products:

Testing and Certification:

Tempshield™ products are thoroughly tested at either nationally approved independent laboratories or leading universities. Tests are performed to current American Society of Testing and Materials (ASTM) standards when a standard exists. For a copy of an actual test report, please e-mail us at customer.support@insulationstop.com.

Air Space Requirements:
Metal and Steel Building Air Space Requirements

Installation Instructions:
Metal and Steel Building - New Wall - Installation Instruction

1. Installed with 3/4" Thermal Breaks

  • The Tempshield™ Insulation is installed with the “white side” towards the interior of the building.
  • Install Tempshield™ Reflective/Bubble/Bubble/White product vertically, using 1 1/4” self tapping screws to secure the insulation to the exterior of the C or Z girts.
  • Tape the seams with a Tempshield™ Foil Tape (goal is an air-tight, snug seam seal).
  • Install a 3/4” thermal break and attach corrugated metal exterior finish.

2. Installed with a 3/4" Drape in Product (No Thermal Break)

  • Per instructions above without the thermal break.
  • When installing the product, insure there is a drape (towards the interior) of at least 3/4” at the center of the cavity.