Items in cart: 0    Total: $0.00
(518) 339-5510
Shop Navigation:
Special Offers
Newsletter
Newsletter
 

Metal and Steel Building - New Roof White

Metal Steel Building New Roof with Thermal BreakProduct: Reflective One Side



Open Interior with 3/4" Thermal Breaks
R-5.5* Heat Flow Down
R-4.1* Heat Flow Up


Open Interior with 3/4" Thermal Breaks and a Nominal 3/4" Drape
R-4.0* Heat Flow Down
R-3.2* Heat Flow Up


* Includes thermal resistance of 0.61 UP and 0.92 DOWN for interior air film.

Calculation Disclaimer: All values are calculated based on the "ASHRAE Handbook of Fundamentals". Heat flow up and down

Tempshield™ Insulation products are a group of technologically advanced materials. They are ideal for new construction or retrofit applications in commercial, industrial, metal and post/frame buildings, along with many other DIY applications. When Metal Steel Building New Roof without Thermal Breakyou think of insulation, you should think of Tempshield™. Our products are recognized for their thermal performance, easy installation, versatility, price and environmental friendliness.

Standard Size Recommended Products:

Custom Size Recommended Products:

Benefits:

  • Easy to handle and install
  • Convenient roll sizes
  • Class A / Class 1 Fire Rating
  • Inhibits dew point condensation
  • Vapor retarder (0.02 perms)
  • Does not compress, collapse or disintegrate
  • Non-toxic / non-carcinogenic

Testing and Certification:

Tempshield™ products are thoroughly tested at either nationally approved independent laboratories or leading universities. Tests are performed to current American Society of Testing and Materials (ASTM) standards when a standard exists. For a copy of an actual test report, please e-mail us at customer.support@insulationstop.com.

Air Space Requirements:
Post Frame Building Air Space Requirements

Installation Instructions:
Post Frame - New White Roof Above and Below Purlin- Installation Instruction

1. Metal Roof with Product below Purlin (first illustration)

  • The Tempshield™ Insulation is installed with the “white side” towards the interior of the building.
  • After the trusses are set, run two purlins to make sure the trusses stay true.
  • Attach the Tempshield™ Reflective/Bubble/Bubble/White product to the first truss with at least 5/16” staples. Temporarily nail a 2”x 4” block over the end of the product to prevent it from pulling away.
  • Roll out the product across the top of the trusses, pull tight and staple.
  • Run subsequent courses of the product with a 3/4” overlap at the seams.
  • Tape the seams with a Tempshield™ Foil Tape (goal is an air-tight, snug seam seal).
  • Install purlins over the insulation. Nail or screw to the trusses through the product.
  • Install the metal roof to the purlins.

Benefits:

  • Easy to handle and install
  • Convenient roll sizes
  • Class A / Class 1 Fire Rating
  • Inhibits dew point condensation
  • Vapor retarder (0.02 perms)
  • Does not compress, collapse or disintegrate
  • Non-toxic / non-carcinogenic

Testing and Certification:

Tempshield™ products are thoroughly tested at either nationally approved independent laboratories or leading universities. Tests are performed to current American Society of Testing and Materials (ASTM) standards when a standard exists. For a copy of an actual test report, please e-mail us at customer.support@insulationstop.com.

Air Space Requirements:
Metal and Steel Building Air Space Requirements

Installation Instructions:
Metal and Steel Building - New Roof White - Installation Instruction

1. Open Interior with 3/4" Thermal Breaks

  • The Tempshield™ Insulation is installed with the “white side” towards the interior of the building.
  • After the red metal is erected, install the Tempshield™ Reflective/Bubble/Bubble/White product over the purlins by using 1/2” self-taping metal screws and screwing the foil to the purlins.
  • Tape the seams with a Tempshield™ Foil Tape (goal is an air-tight, snug seam seal).
  • Install at least a 3/4” thermal break. If installing a standing seam roof, use clips with thermal breaks.
  • Install roofing either by screwing corrugated metal screws through the thermal break and insulation to the purlin or install a standing seam roof.

2. Open Interior with 3/4" Thermal Breaks and a Nominal 3/4" Drape

  • Per instructions above without the thermal break.

Important: Review These Important Safety Guidelines Prior to Installation.