InfraStop® 2″ x 25′ Spiral Pipe Wrap Insulation – Case of 6
$62.10
- R-2.0
- Fiber and Dust Free
- Easy to Install
- Environmentally Safe
- Resists Mold and Fungi
InfraStop® reflective double bubble insulation is great for pipe wrap applications because the product is so easy economical and easy to install. There is a mix of product types and installation configurations available. InfraStop® Pipewrap Insulation achieves an R 4.0 and is excellent for reducing condensation on cold pipes. The product does not create fibers or dust that would require protective garments or a respirator. The rolls are cut to a very convenient size and can easily be molded or cut to your specific application.
- Description
- Additional Info
- InfraStop® Specs
Description
InfraStop® Insulation consists of one outer layer of metalized polyester and one layer of white polyethylene for strength. Each layer is bonded to a tough layer of polyethylene for strength. Two inner layers of insulating bubbles resist conductive heat flow while a center layer of polyethylene gives InfraStop® high reliability and strength.
YouTube ID | CmUtqL0_tNU |
---|---|
Vimeo ID | N/A |
Model Number | ISPWS2256 |
Roll Width | 2 Inch |
Roll Length | 25 Feet |
Per Roll Square Foot | 4.1666 |
Bubble Layer | Double |
Edge Detail | Staple Tab |
Nominal Thickness | 5/16 Inch (.312) |
Weight | .80 oz per square foot |
Reflectance (IR) | 94% + Metal Side |
Emittance | Less than 0.06 Metal Side |
Temperature Range | -60 to +180 degrees F |
Fire Rating | Class A / Class 22 |
Fungi Resistance | No Growth |
Flame Spread Index (ASTM E-84) | Less than 25 |
Smoke Developed Index (ASTM E-84) | Less than 50 |
Pliability | No Cracking / No Delamination |
Bleeding and Delamination | Passed |
Linear Shrinkage | None |
Permeance After Aging | 0.01 |
Permeance Before Aging | 0.023 |
Elevated Temperature & Humidity Resistance: Delamination | None |
Elevated Temperature & Humidity Resistance: Loss of Metalization | None |
Elevated Temperature & Humidity Resistance: Corrosion | None |
Testing & Certifications
All tests on InfraStop® Insulation products are performed at either nationally
approved independent laboratories or at leading universities. Tests are
performed to current American Society of Testing and Materials (ASTM)
Standards when a standard exists.
Testing results on our Reflective Insulation (Reflective/Bubble/Bubble/
Reflective) product are listed below. For any additional testing information
for this product (or any other), please feel free to call or contact us.
Product Standards
Resistance to fungi or bacteria: InfraStop® does not promote the growth of
fungi or bacteria.
Specification compliance: InfraStop® is covered under the Federal Minimum Standards Code for reflective insulation (HH-I-1252B) for all H.U.D. and F.H.A. projects.
Testing and Certification Documents
- Thermal Performance ASTM C1363
- Thermal Performance of Wall Systems ASTM C1363
- Thermal Performance ASTM C335
- Thermal Performance of Crawl Space ASTM C1363
- Hot Surface Performance ASTM C411
- Heat Transfer (Heat Flow Up, Down, Horizontal) ASTM C1363
- Thermal Performance of InfraStop™ and Fiberglass in Walls ASTM C1363
- Heat Transfer of Air-Handling Ducts with InfraStop™
- Flame Spread and Smoke Density ASTM E84
- Fungus Resistance Mil-Std 810B Method 508
- Pliability Test
- Sound Absorption Test ASTM C423-90a and ASTM E795-83
- Sound Transmission Loss ASTM E90-90 and ASTM E413-87
- Water Vapor Transmission ASTM E96
- Tensile Strength
- Emittance Testing
- Thermal Performance of Water Heater Jackets
- Intertek: Surface Burning Characteristics of Building Materials ASTM E84-08
(Taped Joint Detail) Test Report # 3166908SAT-012 - Intertek: Surface Burning Characteristics of Building Materials ASTM E84-08
(Unslit) Test Report # 3166908SAT-011 - R&D Services: Resistance to the Growth of Fungi ASTM C1338-00 Test Report
# RD072713FR - State of California
- State of California Licensed Insulation Manufacturer
- State of Minnesota: Filed with Minnesota Insulation Standards
Program - State of Wisconsin: Wisconsin Material Approval, Safety and Buildings
Division Approval # 920088-1 - R&D Services Emittance Testing
- R&D Services: Physical Properties Sheet Width, Length, Pliability, Water Vapor
Permanence and Aged Water Vapor Permanence - R&D Services: Water Vapor Transmission Test ASTM-E96 (Dessicant Method